Relevant pole data and other factors Corresponding calculated key values

Total length of pole (m)

Height of pole above ground (m)

Diameter of pole at ground

level (mm)

Load to be applied in pole-top deflection test

(N)

Maximum permitted deflection in pole-top

deflection test (mm)

2.6 2.0 110 135.4 100

3.1 2.5 120 143.4 125

3.6 3.0 128 152.0 150

4.1 3.5 135 161.0 175

4.6 4.0 146 171.6 200

5.2 4.5 155 182.3 225

5.7 5.0 164 193.6 250

6.3 5.5 173 205.4 275

6.9 6.0 170 213.7 300

7.4 6.5 178 225.9 325

8.0 7.0 186 238.6 350

8.6 7.5 194 251.8 375

9.2 8.0 202 265.5 400

9.8 8.5 210 279.7 425

10.4 9.0 218 294.3 450

11.0 9.5 226 309.4 475

11.6 10.0 237 326.8 500

13.4 11.5 290 463.4 575

14.0 12.0 300 504.0 400

NOTES: 1. Relevant pole data is based on a shape factor of 0.7 and a calculated wind pressure of 500.14 Pa (relating to a wind speed of 103.9km/h).

2. Corresponding calculated key values are based on a luminaire surface area of 0.2m2 with a shape factor of 1.